3.8.10.1 Loading and saving the arbitrary function
The 100 sequences of the arbitrary function, which can be manually congured with the control panel of the device
and which are applicable either to voltage (U) or current (I), can be saved to or loaded from a common USB ash
drive via the front side USB port. Generally, all 100 sequences are saved or loaded using a text le of type CSV
(semicolon separator), which represents a table of values.
In order to load a sequence table for the arbitrary generator, following requirements have to be met:
• The table must contain exactly 100 rows with 8 subsequent values (8 columns, separated by semicolons) and
must not have gaps
• The les must be stored inside a folder called HMI_FILES which has to be in the root of the USB drive
• The le name must always start with WAVE_U or WAVE_I (not case-sensitive)
• Values with decimal places must use the comma as decimal separator
• All values in every row and column have to be within the specied range (see below)
• The columns in the table have to be in a dened order which must not be changed
Following value ranges are given for use in the table, related to the manual conguration of the arbitrary generator
(column headers like in Excel):
Column Parameter Range
A AC Start 0...50% U or I
B AC End 0...50% U or I
C Frequency Start 0...1000Hz
D Frequency End 0...1000Hz
E Start angle AC 0...359°
F DC Start 0...(Nominal value of U or I) - AC Start
G DC End 0...(Nominal value of U or I) - AC End
H Time in μs 100...36.000.000.000 (36 billion μs)
For details about the parameter and the arbitrary function refer to „3.8.10. Arbitrary function“.
Example CSV:
The example shows that only the rst two sequences are congured, while all others are set to default values. The
table could be loaded as WAVE_U or WAVE_I when using, for example, the model ELR 9080-170, because the
values would t both, voltage and current. The le naming, however, is unique. A lter prevents you from loading
a WAVE_I le after you have selected “Arbitrary --> U” in the function generator menu. The le would not be listed
as selectable at all.
► How to load a sequence table (100 sequences) from a USB ash drive:
1. Do not plug the USB drive yet or remove it.
2. Access the function selection menu of the function generator with
MENU -> Function Generator -> Arbitrary.
3. Tap touch area , then and follow the instructions
on screen. If at least one valid les has been recognized (for le and
path naming see above), the device will show a list of les to select
from with .
4. Tap touch area in the bottom right corner. The selected le is then checked and loaded, if valid.
In case it is not valid, the device will show an error message. Then the le must be corrected and the
steps repeated.