As soon as an event is set up with an action other than “NONE” and with accepted settings, an incident can occur
whether the DC input is switched on or off. On leaving the pages “User events” or “Settings” an event can be
directly displayed.
User events are an integral part of the actual user prole. Thus, if another user prole, or the
default prole, is selected and used, the events will be either differently or not congured.
The set values can be entered using the ten-key tab. This will appear by tapping the touch area
on the particular page, e.g. “4.1 Event U”, showing the rotary knob assignments.
3.6 Control panel (HMI) lock
In order to avoid the accidental alteration of a value during manual operation, the rotary knobs or the touchscreen
can be locked so that no alteration of values will be accepted without prior unlocking.
► How to locking the HMI:
1. In the main page, tap the lock symbol (upper right corner).
2. In the settings page you can select between the complete HMI (“Lock all”) lock or
except for the On/Off button (“ON/OFF possible”)
3. Activate the lock with . The status “Locked” is displayed as .
If an attempt is made to alter something whilst the HMI is locked, a requester appears in the display asking if the
lock should be disabled.
► How to unlock the HMI:
1. Tap any part of the touchscreen of the locked HMI, or turn one of the rotary knobs or press the button “On/
Off” (in complete lock situation).
2. This request pop-up will appear: .
3. Unlock the HMI by tapping on “Tap to unlock” within 5 seconds, otherwise the pop-up will disappear and
the HMI remains locked.