User Manual

Page 43
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
www.elektroautomatik.de
ea1974@elektroautomatik.de
ELR 9000 Series
3.3.3.5 Menu “About HW, SW...”
This menu page displays an overview of device relevant data such as serial number, article number etc.
3.3.3.6 Menu “Function Generator”
See „3.8 The function generator“ on page 56.
3.3.3.7 Menu “Communication”
Here settings for digital communication via the optional interface modules (abbr. IF) of the IF-AB series are made.
The touch area “Congure interface” opens one or more settings pages, depending on the module in use.
For all Ethernet interfaces with two ports: „P1“ is related to port 1 and „P2“ to port 2, like printed
on the module face. Two-port interfaces will use one IP only.
IF Level 1 Level 2 Level 3 Description
Ethernet / ModBus-TCP, 1 & 2 Port
IP Settings DHCP The IF allows a DHCP server to allocate an IP address, a subnet
mask and a gateway. If no DHCP server is in the network then net-
work parameters will be set as dened in point “Manual”
Manual IP This option is activated by default. An IP address can be maually
allocated.
Gateway Here a gateway address can be allocated if required..
Subnet Here a subnet mask can be dened if the default subnet mask is
not suitable.
DNS 1 Here the addresses of the rst and second Domain Name Servers
(DNS) can be dened, if needed. A DNS is only necessary if the
device has Internet access and should call Internet URLs, e.g. an
internal eMail system, in order to send an eMail.
DNS 2
Port Range: 0...65535. Default ports:
5025 = Modbus RTU (all Ethernet interfaces)
502 = Modbus TCP (Modbus-TCP interface only)
IP Com
Settings P1
IP Com
Settings P2
AUTO Settings for the Ethernet port such as transmission speed are set
automatically.
Manual Half dup Manual selection for transmission speed (10MBit/100MBit) and
duplex mode (full/half). It is recommended to use the “AUTO” option
and only revert to “Manual” if these parameters fail.
Full dup
10MBit
100MBit
Host name Free choice of host name (default: Client)
Domain name Free choice of Domain (default: Workgroup)
SMTP
Settings
Server IP Mail server address, used to send eMails via this mail server, in
order to e.g. report an alarm.
Username Login to Mailserver, Username
Password Login to Mailserver, Password
IF Level 1 Description
Probus DP
Node Address Selection of the Probus or node address of the device within range 1...125 via
direct input
Function Tag String input box for a user-denable text which describes the Probus slave function
tag. Max. length: 32 characters
Location Tag String input box for a user-denable text which describes the Probus slave location
tag. Max. length: 22 characters
Installation Date String input box for a user-denable text which describes the Probus slave instal-
lation date tag. Max. length: 40 characters
Description String input box for a user-denable text which describes the Probus slave.
Max. length: 54 characters
IF Level 1 Description
RS232
-
There are no congurable parameters for this module. It always uses these serial
settings: Baud rate = 115200 Baud, 8 data bits, 1 stop bit, parity = none