ASSEMBLY AND INSTALLATION
INSTRUCTIONS
WARNING: BE SURE TO SHUT OFF POWER AT THE MAIN FUSE OR CIRCUIT
BREAKER BOX BEFORE INSTALLING OR SERVICING THIS FIXTURE.
NOTE: 1. Before installing, consult local electrical codes for wiring and grounding requirements.
2. Customer Service: 1-800-887-6326 (weekdays 9 a.m. – 5 p.m. CST)
3. READ AND SAVE THESE INSTRUCTIONS.
130318
352-5969
1. Attach nipple(-a) to the mounting strap, then secure
it with a washer and hex nut.
2. Attach the mounting strap to the outlet box by using
two mounting screws.
3. Secure the top loop to the nipple(-a).
4. Secure the loop onto the stem.
5. Adjust the arms of the main fixture according to the
drawing of the package.
Important:
a. The arms should be positioned with equal
distances between them.
b. The arms should be fixed securely.
6. Choose the length of the chain you need, then
weave the fixture wire and the fixture grounding
wire through the chain, collar and canopy.
7. Connect one end of the chain with the loop by using
a loop lock.
8. Connect the other end of the chain with the top loop
by using another loop lock.
9. Thread the fixture wire and fixture grounding wire
through the top loop, nipple and mounting strap.
10. Pull out the outlet wires and house grounding wire
from the outlet box. Connect wires:
---The smooth wire (marked) from the fixture to the
black wire from the power source.
---The ridged wire (unmarked) from the fixture to
the white wire from the power source.
---Attach the fixture grounding wire to the mounting
strap with the green grounding screw. Then
connect it to the house grounding wire with a
wire nut.
Carefully put the wires back into the outlet box.
11. Attach the canopy to the mounting strap by inserting
the top loop, then secure it with the collar.
12. Attach the glass shadeds onto the glass holders,
secure them with socket rings.
Loop
Canopy
Loop Lock
Loop Lock
Collar
Chain
Outlet Box
House Grounding Wire
Wire Nut
Fixture Wire
Fixture Grounding Wire
Mounting Strap
Green Grounding Screw
Mounting Screw
Nipple (-a)
Top Loop
Hex Nut
Washer
Finial-1
Arm
Socket Ring
Glass Shade
Glass Holder
Bulb Type A Max.100W
(not included)
Cover
Fixture
Nipple(-b)
Hardware Package:
(1 SET)
Finial assembly
Stem