User's Manual

September 06, 2022
CLS-4-420-TH
13
NOTE: The CLS-4-420-TH should not be shipped with the internal baery installed. When transporng
a portable gateway, the lithium-ion baery should be removed and shipped separately using an
approved UN/DOT 38.3 shipping container.
RESET
The CLS-4-420-TH may be reset at any me by pressing and holding both the PB1 and PB2 buons for
at least 4 seconds. The CLS-4-420-TH will need to be re-paired aer a reset.
SPECIFICATIONS
Parameter
Descripon
Power
Overvoltage Category
1
Supply Voltage (DC Input)
7.00 DC to 15.00 VDC (2.5 × 5.5 mm Barrel Jack)
Supply Current (DC Input)
8.1 mA @ 4.00 VDC, 25 °C Ambient
Baery
Manufacture
Panasonic or Samsung
Part Number
NCR18650B or INR18650-35E
Rated Capacity
3400 mAh
Nominal Voltage
3.60 VDC
Over-Voltage Protecon
4.215 VDC
Under-Voltage Protecon
2.50 VDC
Over-Current Protecon
3.6 A Charge, 4.8A Discharge, 14.6 A Short-Circuit
Over-Temperature Protecon
> 50 °C Charge Disabled, > 65 °C Discharge Disabled
Under-Temperature Protecon
< 0 °C Charge Disabled
Environmental
Protecon Rang
IP30
Polluon Degree
2
Operang Temperature
-40 °C to 75 °C
Internal Baery Charge Disabled above 50 °C
Internal Baery Charge Disabled below 0 °C
Internal Baery Discharge Disabled above 65 °C