User's Manual
September 06, 2022
CLS-4-420-TH
12
INTERNAL BATTERY
A 3300 mAh lithium-ion baery is installed in the CLS-4-420-TH to provide power in the absence of AC/DC
adapter and USB connector. The internal baery provides power to the external interfaces, the Bluetooth
Link, and the 2x6 pin connector circuitry.
The baery is accessed by removing the baery cover on the right side of the CLS-4-420-TH enclosure.
The Red 'Bat Low' LED will turn on when the wireless sensor detects that less than 500 mAh is remaining
in the internal baery. The internal baery may be recharged in the CLS-4-420-TH by connecng either
the included AC/DC power adapter (CUI Inc. SWI24-12-N-P6), or via a USB connecon to a PC or
dedicated USB charging device. The approximate charging mes for each method are provided in the
table below:
Charging Method
Maximum Charging Current
Charge Time (80% / 100%)
AC/DC Adapter
1.5 A
2.2 hours / 3.2 hours
USB
500 mA
6.6 hours / 7.6 hours
The 'Bat Low' LED will automacally turn o once more than 1000 mAh of capacity has been returned
to the internal baery during a recharge.
The CLS-4-420-TH contains protecon circuitry that automacally disables baery charge operaon
when the baery temperature is below 0 °C or above 50 °C. The baery will connue to provide power
if charge operaon is inhibited. Charge operaon will resume once the temperature returns to within
the permissible range.
The CLS-4-420-TH will disable all operaon once baery temperature exceeds 65 °C. Discharge operaon
will resume once the temperature drops below 55 °C.