Assembly Instructions
FEBRUARY 11, 2022
CLS-4-420-th
19
INTERMEDIATE ASSEMBLY PROCEDURE
PRECAUTION
This procedure involves the handling of ESD sensive components.
ESD protecon measures should be employed.
COMPONENT LIST
Descripon
Manufacture
Part Number / Revision
X-Lab CLS-4-420-TH Main CCA
Electronics4All
Rev. 1.0
X-Lab
CLS-4-420-TH
Enclosure
Assembly
Electronics4All
Rev. 1
Lithium-Ion Baery
Panasonic
NCR18650B
2AG Fuse
Eaton
BK/C519-125-R
4 x Screw 4-40 x 5/16
McMaster-Carr
90380A107
1 x Screw M3 x 8 mm
McMaster-Carr
92005A118
TOOLS AND MATERIAL LIST
1.
10 mm Socket and Adapter
2.
#1 Phillips Bit
3.
Torque Screwdriver
4.
Conducve Tweezers
PROCEDURE
1
Remove the washer and nut from the DC
input connector on the main CCA
2
Feed the DC input jack through the
opening in the le housing. The thread
slot should face towards the rear of the
housing.