Assembly Instructions
FEBRUARY 11, 2022
CLS-4-420-th
16
9
Select programming from the Top menu,
select the appropriate gas gauge image le,
and then select Program. A progress bar
dialog will display the programming status.
Aer that successful message will appear at
le boom corner.
10
Select Calibraon from the top menu. The
calibraon controls will be displayed in the
main window.
11
Select the CC Oset and Board Oset
checkboxes. Ensure no other boxes are
checked. Select the Calibrate Gas
Gauge buon. This calibraon process
may take up to a minute to complete.
12
A Green checkmark will appear beside
Calibrate Gas Gauge buon when the
process is complete.
13
Deselect the CC Oset and Board
Oset checkboxes. Select the Calibrate
Current checkbox. Enter -1000 into
the applied Current Field.
14
Set the acve load for 1000 mA
constant current. Enable the loaf and
conrm 1000mA ± 5mA is being drawn
from the CCA