Assembly Instructions
FEBRUARY 11, 2022
CLS-4-420-th
14
GAS GAUGE PROGRAMMING PROCEDURE
PRECAUTION
This procedure involves the handling of ESD sensive components.
ESD protecon measures should be employed.
COMPONENT LIST
Descripon
Manufacture
Part Number / Revision
X-Lab CLS-4-420-TH Main CCA
Electronics4All
Rev. 1.0
AC/DC Adapter
CUI Inc.
SWI24-12-N
Serial Number List
Electronics4All
NA
Baery Conguraon File
Electronics4All
Rev. 2.1
TOOLS AND MATERIAL LIST
1.
Computer
2.
Texas Instruments EV2400 Interface Adpater w/ 4-pin cable, USB Type-B cable
3.
Texas Instruments CC2652R1 Development kit w/ Micro-USB cable
4.
JTAG Programming Cable
5.
DC Power Supply (4.0 VDC, 3A Minimum)
6.
DC Acve Load (1.00A Constant Current)
7.
Test Leads
8.
Mulmeter
PROCEDURE
1
Connect the EV2400 Interface Adapter to
the computer.
2
Connect the 4-pin cable from the EV2400
to J200 on the main CCA.