Operating Instructions

January 8, 2021
BMS-1001-TH BMS
19
SPECIFICATIONS
Aspect
Descripon
Power
Overvoltage Category
1
Supply Voltage (DC Input)
7.00 DC to 15.00 VDC (2.5 × 5.5 mm Barrel Jack)
Supply Current (DC Input)
1.50 A @ 12.00 VDC, 25 °C Ambient (Internal Baery Charging)
Supply Voltage (Lead-Acid)
11.00 to 36.00 VDC (External Lead-Acid Baery String)
Supply Current (Lead-Acid)
9.9 mA (ON), 6.3 mA (OFF) @ 25.00 VDC, 25 °C Ambient
Baery
Manufacturer
Panasonic
Part Number
NCR18650B
Rated Capacity
3400 mAh
Nominal Voltage
3.60 VDC
Over-Voltage Protecon
4.215 VDC
Under-Voltage Protecon
2.50 VDC
Over-Current Protecon
3.6 A Charge, 2.8 A Discharge, 14.6 A Short-Circuit
Over-Temperature Protecon
> 45 °C Charge Disabled, > 60 °C Discharge Disabled
Under-Temperature Protecon
< 10 °C Charge Disabled
Environmental
Protecon Rang
IP30
Polluon Degree
2
Operang Temperature
-20 °C to 60 °C
Internal Baery Charge Disabled above 45 °C
Internal Baery Charge Disabled below 10 °C
Internal Baery Discharge Disabled above 60 °C
Storage Temperature
-20 °C to 50 °C
Permissible Humidity
20 % to 85 % (Operaon and Storage)
Maximum Altude
2000 m