Operating Instructions
January 8, 2021
BMS-1001-TH BMS
10
BATTERY BANK WIRING
TERMINAL PLUG
The 6-pin baery cell input terminal receptacles are designed to mate with Phoenix Contact Terminal
Block Plug 1827745.
WIRE CONNECTIONS
Ferrules required on all wire input connecons to prevent loose wire strands from contacng adjacent
terminals. The Phoenix Contact 1827745 terminal plug accepts the following:
Connecon Type
Ferrule Tip Cross Secon
Conductor cross secon exible, with ferrule
without plasc sleeve
0.25 mm
2
to 1.5 mm
2
Conductor cross secon exible, with ferrule with
plasc sleeve
0.25 mm
2
to 0.5 mm
2
2 conductors with same cross secon, stranded,
with ferrule without plasc sleeve
0.25 mm
2
to 0.34 mm
2
2 conductors with same cross secon, stranded,
with TWIN ferrules with plasc sleeve
0.5 mm
2
Screw heads should be ghtened between 0.22 Nm to 0.25 Nm.
INPUT RATINGS
1. Each individual cell voltage should not exceed 5.00 VDC
2. The sum of all individual cell voltages connected to a BMS should fall within the range of 11.00 VDC
to 36.00 VDC
Cauon: The maximum applied voltage between adjacent baery cell inputs should not
exceed 5.00 VDC, and the maximum applied voltage between cell input 0 and cell input 10
should not exceed 36.00 VDC.