Operating Instructions

January 8, 2021
BMS-1001-TH BMS
10
BATTERY BANK WIRING
TERMINAL PLUG
The 6-pin baery cell input terminal receptacles are designed to mate with Phoenix Contact Terminal
Block Plug 1827745.
WIRE CONNECTIONS
Ferrules required on all wire input connecons to prevent loose wire strands from contacng adjacent
terminals. The Phoenix Contact 1827745 terminal plug accepts the following:
Connecon Type
Ferrule Tip Cross Secon
Conductor cross secon exible, with ferrule
without plasc sleeve
0.25 mm
2
to 1.5 mm
2
Conductor cross secon exible, with ferrule with
plasc sleeve
0.25 mm
2
to 0.5 mm
2
2 conductors with same cross secon, stranded,
with ferrule without plasc sleeve
0.25 mm
2
to 0.34 mm
2
2 conductors with same cross secon, stranded,
with TWIN ferrules with plasc sleeve
0.5 mm
2
Screw heads should be ghtened between 0.22 Nm to 0.25 Nm.
INPUT RATINGS
1. Each individual cell voltage should not exceed 5.00 VDC
2. The sum of all individual cell voltages connected to a BMS should fall within the range of 11.00 VDC
to 36.00 VDC
Cauon: The maximum applied voltage between adjacent baery cell inputs should not
exceed 5.00 VDC, and the maximum applied voltage between cell input 0 and cell input 10
should not exceed 36.00 VDC.