User manual
Bijou
67
with that Submaster go on to the maximum re-
corded output and all other channels from all
other sources go to OFF. This is a LAST ACTION
mode of operation.
OFF: When a Submaster is set to OFF, both its
fade handle and bump button are disabled.
TIMED SUBMASTERS
At the bottom of the Sub Preview Screen, are
three windows: Time Up, Hold, and Time Down
(see Figure 78). The time features work with
either the NORM or INHB modes of operation
and are activated by the Submaster’s bump but-
ton. The first press of the [Time] key allows you to
set a time for the Submaster to fade from OFF to
FULL output. The second press of the [Time] key
allows you to set how long the Submaster’s out-
put remains at FULL. The third press of the
[Time] allows you to enter the time it takes the
output to fade to OFF once the delay is over.
Example:
To see how this works:
1. Use Pg:1 Sub: 1.
2. Press [Time] [5] [Time] [3] [Time] [2] [Enter].
This sets a 5 second fade up, a hold time of 3
seconds, and a 2-second fade out.
3. Go to the Stage Screen ([Stage]).
4. Press and release the bump button for Pg: 1
Sub: 1. The Submaster outputs automatically
change based on the times entered.
It is possible to have a timed Submaster fade up
to FULL and remain ON until you press the bump
button a second time to start the fade out.
Example:
1. Go back to the Sub Preview Screen.
2. Press [Time] [Time] [FL]. In the command line
at the lower left of the screen, now appears
HOLD FOREVER.
3. Press [Enter].
4. Go back to the Stage Screen.
5. Press the Pg: 1 Sub: 1 bump button. The lev-
els fade up and stay ON until you press the
bump button again to start the fade out.
Figure 78-Time Up, Hold, and
Time Down Windows of the
Sub Preview Screen