Operation Manual
-49-
8.1. Cancel Report
The Cancel Report function enables you to prevent the system from reporting in the
event of a false alarm.
To cancel report:
x From the main menu, select Cancel Report [1]; all pending messages to
the monitoring service are canceled.
8.2. Zone Bypassing/Unbypassing
When a zone is bypassed, its detector is ignored by the system and does not generate an
alarm when triggered.
To bypass or unbypass a zone:
1. From the Bypass Zones menu, select Bypass/Unbyp. [21].
2. Using the arrow keys, scroll to the zone you want to bypass or
unbypass.
3. Press dž to change the bypass status.
4. Press ̙; Save Changes? is displayed.
5. Press dž to confirm the changed bypass status.
To unbypass all zones:
1. From the Bypass Zones menu, select Unbypass All [22].
2. Press dž; all zones are unbypassed
All bypassed zones will be automatically unbypassed when the system is disarmed.
A fire zone cannot be bypassed.