Operation and programming manual

21
Address 10: PGM Options
The PGM (Programmable Output) can be used for indication of certain status or trouble
conditions. When the PGM output is activated terminal 9 switches to ground. Choose
the PGM output setting from the following table.
Value Type Activated By Deactivated By
00 PGM Disabled --- ---
01 System Status System Armed System Disarmed
02 System Status Entry/Exit Tone Follower Entry/Exit Tone Follower
04 System Status System in Communication End of Communication
08 System Trouble AC Loss AC Restore
10 System Status Bell Follower Bell Follower
Event Codes
All events can be programmed to transmit a two digit event code message to the
central station. These codes are usually assigned by the central station - consult the
central station operator/owner for a listing of the different event codes. To disable an
event code program the code as 00. To disable communications program all event
codes as 00.
Address 11: Alarm from Zone 1*
Address 12: Alarm from Zone 2*
Address 13: Alarm from Zone 3*
Address 14: Alarm from Zone 4*
Address 15: Alarm from Tamper Zone*
Address 16: [P] Key alarm*
Address 17: [F] Key alarm*
Address 18: [E] Key alarm
*
Address 19: Zone 1 Restore
Address 20: Zone 2 Restore
Address 21: Zone 3 Restore
Address 22: Zone 4 Restore
Address 23: Tamper Zone Restore
Address 24: [P] Key alarm restore
Address 25: [F] Key alarm restore
*
When using the Follow-me feature, program these addresses with a value greater than 00.