4.3: Programming Parameters
The following section lists the Penta’s programming parameters which are used to
configure the system. For a listing of the default parameters please contact your local
dealer.
Address 01: Miscellaneous
This address offers a number of options regarding the system set-up. Enter 5 digits at
this address according to the following:
0
First Digit:
P and E Key Function
0 - P and E Audible Alarms
1 - E Audible Alarm, P Silent Alarm
2 - E Silent Alarm, P Audible Alarm
3 - P and E Silent Alarms
Fifth Digit:
Keypads
0 - No Keypads
1 - One Keypad
2 - Two Keypads
3 - Three Keypads
Fourth Digit:
Tamper Zone Definition
0 – Arm/Disarm Keyswitch
4 - Tamper Zone
Third Digit:
Keyswitch Function
0 - Latching
8 - Momentary
Address 02: Communication Options
This address consists of the various options used in communication and/or remote
programming. Enter five digits according to the following.
First Digit:
Dialing
0 - Pulse
1 - DTMF
Fifth Digit:
Protocol
0 - 20pps 4/2 No Parity
1 - Follow Me
Fourth Digit:
Handshake
0 - 1400Hz Handshake
2 - 2300Hz Handshake
Second Digit:
RP Access Type
0 - Passcode
8 - Callback
Third Digit:
RP Access
0 - Disable RP Access
4 - Enable RP Access