Installation guide

6
3.4.1. Detectors
The CommPact supports 33 security zones. Only one detector can be registered to each
zone. Zones 1-32 are intended for wireless detectors by default. Zone 33 is an on-board
hardwire zone (can be configured as NO, NC or EOL).
Step 1: Register a detector
1. Go to the main menu and select [9]>[1]>[1] (Programming> Devices > Zones)
2. Using the arrow keys, select a specific zone and press
''. The system initiates
Registration mode.
3. Send two transmissions from the detector. A confirmation sound is heard after
each successful signal (chime sound). After two successful transmissions a
confirmation beep is heard.
Sending the transmissions can be done in several ways, as summarized in
Table 2.
Device
Device Model
Number
Sending Transmissions
PIR Detectors
EL-2645
EL-2645PI
Apply battery power. Place the mode
jumper over pins 2 and 3 (Radio Mode);
the LED flashes.
OR
Depress the tamper switch twice, in rapid
succession.
Magnetic Contact EL-2601
When you apply battery power and the
tamper switch is open, the device enters
test mode in which a transmission is sent
every few seconds. You can terminate the
test mode by closing the tamper switch.
Flood Sensor EL-2661
Universal
Transmitter
EL-2602
Glass break EL-2606
Smoke Detector EL-2603
Press the test button. Verify that the
transmission LED is lit momentarily. Wait
five seconds and press the test button
again.
Table 2: Transmission sending
4. After the detector is successfully registered the display shows: 'Save?'
Press
'' to confirm and continue entering other parameters for the chosen
device (see section below) or press X to go back and enroll additional zones.
Step 2: Set detector's parameters
1. Go to the main menu and select [9]>[1]>[1] (Programming > Devices > Zones)
2. Using the arrow keys select a specific zone and press
''.
3. Set the main parameters for each zone, according to Table 3