System information
11
Click Continue to complete scanner preparation.
Next steps
The next step is to calibrate the Fiery Server.
Calibrate the Fiery server
You perform ColorCal calibration using the grayscale strip and the ColorCal measurement page.
Before you begin
For this procedure, you must have just printed the ColorCal measurement page in Calibrator and, optionally,
prepared the scanner.
1
In Calibrator, under Get Measurements, click Measure.
2
Place the grayscale strip face down on the glass (platen) along the top edge of the glass so that it is centered along
the top edge of the measurement page.
3
Place the ColorCal measurement page face down over the grayscale strip, as indicated on the ColorCal
measurement page. Make sure that the patches on the grayscale strip do not overlap the color patches. Close the
platen glass cover, being careful not to move the grayscale strip and color measurement page.
4
Click Continue to start the ColorCal measurement.
5
Click OK to complete calibration.
6
To apply the measurement data to the Fiery Server, click Apply.
7
To close Calibrator, click Done.
Calibrate with the ES-1000
Using the ES-1000 spectrophotometer, you can measure printed color patches and automatically download the
measurements to the Fiery Server.
1
In Device Center, click General, click Tools, and click Calibrate.
2
In Calibrator, under Select Measurement Method, select the ES-1000.
3
Under Check Print Settings, select a calibration set, either by name or by the print settings associated with the
calibration set.
Note: If more than one calibration set is listed under Check Print Settings, select the calibration set associated
with the output profile you use most often.
4
Under Generate Measurement Page, click Print.
5
Select appropriate options for your measurement instrument and click Print to print the measurement page.
Sorted patches are printed on the page in order of hue and saturation levels. Randomized patches are printed in
random order. Randomized patches can help to compensate for density inconsistencies on different areas of the
page.
6
Under Get Measurements, click Measure and select the options that match the printed measurement page.
7
Click Measure.
Fiery Command WorkStation
Managing color
143