Technical data

3
3-18 Performing Setup from the Control Panel
will not change. If you select No, you proceed to the IP Address option, where you
manually set the IP address.
Select protocol
DHCP/BOOTP/RARP [DHCP]
This option appears only if you answered Yes to Enable Auto IP Conguration.
Select the protocol over which the Fiery should search for its IP address. Both DHCP
and BOOTP allow the Fiery to obtain the Token Ring IP address and Subnet Mask
automatically. RARP obtains only the Token Ring IP address.
Depending on your network, the Fiery might be assigned a different address after you
reboot the Fiery. With the DHCP setting, the Fiery can be assigned a different address
even if it is not rebooted.
Make sure the network is already congured properly for the protocol you select.
Get Gateway Address Automatically
Yes/No [No]
Use this option to get the gateway address automatically for printing with TCP/IP.
This option appears only if you selected DHCP or BOOTP as the protocol in the
previous option.
If you select a DHCP or BOOTP protocol and later change it to RARP, you must
return to Setup and set this option to No. You can then set the address manually. This
is because RARP does not support automatic assignment of the gateway address.
IP Address
[127.0.0.1]
Enter the Fiery IP address for Token Ring. This IP address, unlike an IP address set
automatically, remains the same if you reboot the Fiery. You must change the default
127.0.0.1 to a valid address for your network. For information about setting up