User manual
Lamp Information 3
Installing and Replacing the Lamp
A lamp must be installed before you use the fixture.
Figure-2 Lamp door on bottom of the fixture.
Step 1: Disconnect power to the fixture before installing or replacing the lamp.
Step 2: On the bottom of the fixture, turn the latch on the lamp door one-quarter turn and then
open the door.
Step 3: Remove the lamp holder assembly by turning the knurled knob counterclockwise to
release the lamp socket assembly.
Note:
Verify that the HPL lamp you intend to install is suitable for your facility’s voltage;
115-, 120-, 230-, and 240-volt HPL lamps are available.
See HPL Lamp Table, page 2. Operating HPL lamps above their rated voltage
reduces lamp life and can cause premature lamp failure.
WARNING:
Unplug the fixture and allow it to cool down before attempting to change the
lamp.
Lamp door latch
Lamp door