User manual
5 Service 46
Remove a CEM+ Module:
Step 1: Turn off rack power at the main breaker.
Step 2: Open the rack door.
• Please see Releasing and Securing Module Safety Stops (ESR Racks Only)
above if appropriate.
Step 3: Press the “eject” symbol on the right end of the spring-loaded handle and grab
the other end of the handle, pulling it until it is perpendicular to the face of the
CEM+. The CEM+ will be gently pushed out of the rack as you move the handle.
Step 4: Pull the CEM+ straight out.
Replace a CEM+ Module:
Step 1: Firmly press the new CEM+ module into the correct slot by pressing on the
outside edges until you feel the connections seat (the module face will be flush
with the other modules).
Step 2: Close and lock the Sensor rack door before applying power.
Step 3: ONLY if directed to do so by an ETC-authorized service representative, transfer
the configuration files/information to your new CEM+.
WARNING:
Do not press on the center of the CEM+ to insert it into a rack. Doing so may
result in damage to the CEM+.
ETC CEM+ R 1/ 6 G 9
[Rack OK]
E
Press here to get handle.
Pull handle while pressing .
Press here to insert.