37 Sensor+ CEM+ Configuration Manual
values. Dimmer Doubling is only available for 120V systems.
Currently, Dimmer Doubling works in Advanced Patch mode only. To configure a dimmer
for Dimmer Doubling:
Step 1: Set the rack that contains the dimmer to Advanced Patch mode.
Step 2: Set the dimmer’s firing mode to DimDbl.
Step 3: Re-configure your port settings and data loss behavior for that rack if they were
modified from the defaults.
Step 4: Use advanced patch to patch your dimmers.
You may need to re-patch all of the dimmers if you are not using the default
patch.
You will need to patch the Dimmer Doubled side of the dimmer for each port
you are using (DMXA DD, DMXB DD, EDMX DD).
Property
120V 230V
Firing Mode DimDbl ---
Curve Mod-Square ---
Threshold 1% ---
Min. Scale Voltage 6V ---
Max. Scale Voltage 115V ---
Voltage Regulation Checked ---
Preheat Unchecked ---
Dynamic Preheat 0 sec. ---
DC Output Prevent Checked ---
InRush Protect Unchecked ---