37 Sensor+ CEM+ Configuration Manual
values. Dimmer Doubling is only available for 120V systems.
Currently, Dimmer Doubling works in Advanced Patch mode only. To configure a dimmer
for Dimmer Doubling:
Step 1: Set the rack that contains the dimmer to Advanced Patch mode.
Step 2: Set the dimmer’s firing mode to DimDbl.
Step 3: Re-configure your port settings and data loss behavior for that rack if they were
modified from the defaults.
Step 4: Use advanced patch to patch your dimmers.
• You may need to re-patch all of the dimmers if you are not using the default
patch.
• You will need to patch the Dimmer Doubled side of the dimmer for each port
you are using (DMXA DD, DMXB DD, EDMX DD).
Property
120V 230V
Firing Mode DimDbl ---
Curve Mod-Square ---
Threshold 1% ---
Min. Scale Voltage 6V ---
Max. Scale Voltage 115V ---
Voltage Regulation Checked ---
Preheat Unchecked ---
Dynamic Preheat 0 sec. ---
DC Output Prevent Checked ---
InRush Protect Unchecked ---