mode to Switched and turning on Voltage Regulation does not work.
Fluorescent
Change the firing mode to Fluorescent and click Save Changes. After saving changes,
the remaining dimmer properties will change automatically or can now be set to your
desired values.
Dimmer Doubling™
Change the firing mode to DimDbl and click Save Changes. After saving changes, the
remaining dimmer properties will change automatically or can now be set to your desired
Property
120V 230V
Firing Mode Normal Normal
Curve Linear Linear
Threshold
1%
or desired setting
1%
or desired setting
Min. Scale Voltage
115V
or desired setting
265V
Max. Scale Voltage
115V
or desired setting
265V
Voltage Regulation Checked Checked
Preheat Unchecked Unchecked
Dynamic Preheat 0 sec. 0 sec.
DC Output Prevent Unchecked Unchecked
InRush Protect Unchecked Unchecked
Property
120V 230V
Firing Mode
Fluorescent Fluorescent
Curve Linear Linear
Threshold
1%
or desired setting
1%
or desired setting
Min. Scale Voltage
56V
or desired setting
56V
or desired setting
Max. Scale Voltage
120V
or desired setting
240V
or desired setting
Voltage Regulation Checked Checked
Preheat Unchecked Unchecked
Dynamic Preheat 0 sec. 0 sec.
DC Output Prevent Checked Checked
InRush Protect Unchecked Unchecked