User manual

362 Insight 2x user manual
System Status
System Status is softkey [S4] in the Rack Status and Dimmer Status
displays
Use [S4], System Status, to check information about your Sensor dim-
ming system, including system firing mode, current backup look status,
ETCLink errors, and system configuration.
Thru
Use [Thru] to select a continuous group of dimmers or channels.
Example: [Channel] [1] [Thru] [5] [And] [8] [At] [7][5] sets channel 1 through
5 and channel 8 to 75 percent.
Time
Use [Time] to enter upfade and downfade times for cues and submasters.
Example: [Cue] [6] [Time] [5] [Enter] [1][0] sets cue 6’s upfade to five sec-
onds and its downfade to ten seconds.
Example: [Cue] [7] [Time] [3] [Time] [5] [Enter] sets cue 7’s upfade to three
seconds and its downfade to five seconds.
Time
Time is softkey [S2] in the Real Time Programs display
Use [S2], Time, to go to the time field for editing.
Track
Use [Track] to record channel levels that are to be tracked into subsequent
cues.
Example: [Cue] [5] [Track] [Enter] tracks channels from cue 5 into follow-
ing cues.
Tracked channels
A tracked channel is a channel whose level is unchanged from the preced-
ing cue
.
Tracked channels are displayed in magenta.