User manual

appendix d reference 353
Rate
Rate is softkey [S3] in the Stage, Blind, Fader and List displays
Use [S3], Rate to edit the rate for a cue, submaster, multipart cue, effect,
or subroutine. Also use [S3], Rate, to place the timing for a submaster
under rate wheel control.
Example: [S3], Rate, [Sub Bump 3] followed by adjustment of the rate
wheel modifies submaster 3’s fade times.
Rate (SMPTE)
Rate is softkey [S4] after [S7], More Softkeys, in the Dimmer Status
display
Use [S4], Rate, to access the rate fields in the SMPTE Events display.
Press once to select the A/B cue rate, Press again to select the C/D cue
rate and press once more to select the submaster rate.
Rate Wheel
Use the rate wheel, when one of the fader [Rate] keys is active, to alter
the rate of fades.
Example: Press [AB Rate] then move the rate wheel to adjust the fade rate
of the cue in the A/B fader.
Record
Use [Record] to save all cue, submaster or group information in console
memory
Example: [Record] [6] [Time] [3] [Enter] records cue 6 and sets its fade
time to 3 seconds.
Example: [1] [Thru] [6] [Record] [Sub Bump 1] records channels 1 through
6 to submaster 1.
Record Backup
Record Backup is softkey [S3] in the System Status display
Use [S3], Record Backup, to store a recording of a selected look on stage
in a Sensor CEM. You may record up to 32 backup looks.
Record Loads
Record Loads is softkey [S5] in the Load Management display
Use [S5], Record Loads, to record load information for all dimmers set at
a level above zero. Choose the dimmers you wish to record, set them to
a level, then run Record Loads.