User manual

338 Insight 2x user manual
DMX512 Mode
DMX512 Mode is softkey [S2] in the Input/Output Configuration
display
Use [S2], DMX512 Mode, to set a DMX512 port to multiplex mode or
normal mode. Multiplex mode allows dimmers to be used with ETC
Source 4 multiplexers. Switching from multiplex to normal mode will
cause dimmers on that port to be taken out of the patch.
DMX512 Port
DMX512 Port is softkey [S1] in the Input/Output Configuration display
[S1], DMX512 Port, allows selection of a DMX512 output port to put into
multiplex mode or to change the starting DMX512 number. DMX512
starting numbers may not be changed by the user if any port is in multiplex
mode.
Example: [S1], DMX512 Port, [3] [S2], DMX512 Mode, [Enter] [1] [Enter]
sets port 3 to multiplex mode.
DMX512 Speed
DMX512 Speed is softkey [S4] in the Input/Output Configuration
display
[S4], DMX512 Speed, changes the DMX512 transmission rate to accom-
modate DMX512 receivers that accept data at different rates. Four rates
are available: Max, Fast, Medium, and Slow. The DMX Speed should be
set to Max when used with ETC DMX512 receivers. Other equipment
may require slower speeds.
DMX512 Start
DMX512 Start is softkey [S3] in the Input/Output Configuration display
Use [S3], DMX512 Start, to set the starting dimmer number of a DMX512
port. If any port is in multiplex mode, the starting numbers may not be
changed.
DMX In
DMX In is softkey [S8] after [S7], More Softkeys, in the Stage and Fader
displays
Use [S8], DMX In, in Stage mode to record only the DMX512 input levels
into a cue, group or submaster and in Fader mode to view any DMX512
input to the console.
Example: [Record] [Cue] [8] [S8], DMX In, [Enter] records only the current
DMX512 input levels into cue 8.
Example: [Record] [Cue] [5] [Except] [S8], DMX In, [Enter] records current
live levels on stage, except for those set by DMX512 input, into cue 5.
Down Arrow
Use [] to move through various displays, such as the Effect and Macro
Editing display modes or the Stage and Blind displays.