User manual

chapter 20 control interfaces 239
MSC commands transmitted by Insight 2x
MIDI Show Control (MSC) allows the console to send the following com-
mands to MIDI devices. If MSC output is enabled on the console, the con-
sole automatically sends the MSC commands. The console’s transmitter
Device ID must match the device ID for the MIDI device receiving the sig-
nals.
[A/B Go] If a cue is pending, the console transmits [A/B Go] with
cue number and a list entry of 1.
If a cue is holding, the console transmits [A/B Resume]
with cue number and a list entry of 1.
[C/D Go] If a cue is pending, the console transmits [C/D Go] with
cue number and a list entry of 2.
If a cue is holding, the console transmits [C/D Resume]
with cue number and a list entry of 2.
[A/B Hold] If a cue is running, the console transmits [A/B Stop] with
cue number and a list entry of 1.
[C/D Hold] If a cue is running, the console transmits [C/D Stop] with
cue number and a list entry of 2.
Macros For macros 1-127, the
console
transmits Fire with the
macro number.