chapter 19 sensor dimming 225
Dimmer status
The Dimmer Status display provides information about dimmers, including
size and type, recorded load, firing mode, output curve, rack, slot, panic
mode, and boost. Press [Setup] [9] [Enter] [3] [Enter] to access the
Dimmer Status display.
• Type shows the dimmer’s amperage, and whether the dimmer is
high-rise or standard. (Feedback indicates that the dimmers are Ad-
vanced Features modules.)
• Recorded load displays the load at which the selected dimmer was
recorded.
• Firing mode indicates whether the dimmer is normal, multiplexed, or
switched. "--" indicates a normal firing mode.
• Curve indicates the output curve assigned to the dimmer. "--" equals
00.
• Rack indicates the number of the rack where the dimmer is located.
• Slot indicates the number of the slot in the rack where the dimmer is
located.
• Panic mode indicates whether the dimmer is assigned to a panic cir-
cuit. "--" indicates an unassigned dimmer.
• Boost indicates the dimmer’s Boost level. "--" indicates a Boost level
of 100 percent.
Up to 16 dimmers are shown on the display at once, along with error mes-
sages associated with each dimmer. Press [S5], Select Dimmer, [#]
[Enter] to select a specific dimmer or use [+] and [–] to move through the
list of dimmers a page at a time.