User manual
chapter 19 sensor dimming 221
Clearing dimmer loads
Clear Loads allows you to clear selected dimmer loads, thus disabling
dimmer monitoring for those dimmers. This can be useful if you know that
the load on a dimmer or group of dimmers will change over the course of
a show and don’t want to receive load error messages every time it hap-
pens.
To clear loads, follow these steps:
Keystrokes:
Action:
1. Press [Setup].
Selects Setup display
2. Select [9], ETCLink Func-
tions, and press [Enter].
Selects ETCLink Functions menu
3. Select [4], Load Manage-
ment, and press [Enter].
Selects Load Management display
4. Press [S6], Clear Loads.
(If you wish, you may
enter a specific dimmer or
dimmers to clear.)
Prompt reads:
To clear loads, select dimmer(s) and
press ENTER (Enter 0 to clear loads
for all dimmers)
5. Press [0] [Enter].
Advisory reads:
Recorded loads will be erased for all
dimmers with levels above zero,
disabling load error messages for
those dimmers.
Press [Enter] to proceed, or press
[Clear] to cancel
6. Press [Enter] to proceed
with the load clear, or
press [Clear] to cancel the
operation.
Loads are cleared for all dimmers with
levels above zero
Once complete, advisory reads:
Clear Loads processing has
completed