User manual
220 Insight 2x user manual
5. Press [S4], Load Check.
(You may enter specific
dimmers to check.)
Prompt reads:
To check loads, select dimmer(s)
and press ENTER (Enter 0 to check
loads for all dimmers)
6. Press [0] [Enter].
Advisory reads:
All dimmers with levels above zero
will have their loads checked.
Levels on stage will change while
the Load Check is in progress. The
system will automatically vary the
dimmer outputs during the Load
Check. The process may take
several minutes to complete.
Press [Enter] to proceed, or press
[Clear] to cancel
7. Press [Enter] to proceed
with the load check, or
press [Clear] to cancel the
operation.
Loads are checked for all dimmers
with levels above zero
Once complete, advisory reads:
Record Loads processing has
completed
Press any key to continue