Specifications
352 Appendix B References
RVI ETCNet DIP switch settings
In order to enable the RVI for use on the ETCNet network, you must first
adjust the settings of the two sets of ETCNet DIP switches. You will need
to use a pin or a similar fine-pointed object to set the switches.
To set the switches, follow these steps.
1. Locate the two sets of DIP switches, visible through the right side
panel of the RVI.
2. If the ETCNet cable is plugged into the BNC (ThinNet) connector, set
the back six DIP switches to Off (up). Set the front six to On (down).
3. If the ETCNet cable is plugged into the RJ45 (Twisted Pair) connector
or the DB15 (ThickNet) connector, set the front six switches to Off
(up). Set the back six to On (down).
Installing remote video monitors
You can have additional monitors at remote locations. Connect them to
RIUs or RVIs operating on ETCNet. These remote monitors duplicate the
console’s displays.
Connect monitors to interface devices by following these steps.
1. Insert the female end of the monitor power cord in the monitor
connector, and the male end of the monitor power cord in the
interface device connector labeled Switched outlets.
2. Connect the cable to the connector labeled CRT 1 or CRT 2 on the
interface device.
3. Turn monitor power switch to its On position.
VGA monitor console connector
HD-DB15 female
VGA monitor pinout
1 Red video
2 Green video
3Blue video
4Ground
5Ground
6 Red ground
7 Green ground
8 Blue ground
9 not connected
10 Ground
11 Ground
12 not connected
13 Horizontal (H/V) sync
14 Vertical sync
15 not connected