Specifications

342 Appendix A Installation
Installing remote macros
The console provides eight remote macro inputs through the 25-pin
connector on the back panel labeled Remote Go. A user-supplied remote
device connects to the console via a 24 AWG, aluminum-shielded, multi-
conductor cable with one twisted pair designated for each switch (Belden
9507 S-R PCV Insulated or Alpha 5477 80 Deg. C 300 V PVC). The cable
connector at the remote device will vary depending on the device itself.
Console connector Remote connector
DB-25 female Connector type depends on unit
Pin Function
1 – Macro 1,901
2 – Macro 1,902
3 – Macro 1,903
4 – Macro 1,904
5 – Macro 1,905
6 – Macro 1,906
7 – Macro 1,907
8 – Macro 1,908
9 not connected
10 Ground
11 + 12 Vdc
12 not connected
13 not connected
14 +Macro 1,901
15 +Macro 1,902
16 +Macro 1,903
17 +Macro 1,904
18 +Macro 1,905
19 +Macro 1,906
20 +Macro 1,907
21 +Macro 1,908
22 not connected
23 Ground
24 + 12 Vdc
25 not connected