Specifications
Insight 3 User Manual, v.3.1 329
Setting Insight 3 DIP switches
All consoles check DIP switch settings when the system is turned on. You
must restart the console whenever you change DIP switch settings for
those new settings to take effect.
Insight 3 and later models of Insight 2 and 2x (those without a key type
power switch on the face panel) have recessed DIP switches located near
the middle of the rear panel (shown in Console’s back panel, page 324).
You may toggle these switches up or down from the outside of the
console without raising its face panel. Set these switches as follows.
1. Set DIP switches 2 and 3 to indicate ETCNet network status. (If you
are using Full Tracking Backup, the switches also determine which
console is A and which is B).
DIP 2 DIP 3 Console mode on start up
UPUP Network off
DOWNDOWNNetwork on/Single console
DOWNUPNetwork on/FTB Console A
UPDOWNNetwork on/FTB Console B
2. Set DIP switch 4 for SMPTE.
DIP 4 SMPTE status
UPDisabled
DOWN Enabled
3. Set DIP switch 7 to indicate what kind of wiring you are using.
DIP 7 Wiring type/connector
UPBNC (ThinNet) connector
DOWNRJ45 (Twisted Pair) connector
4. If you are using Twisted Pair wiring, it may be necessary to change
the setting of DIP switch 8. If you are using an external null
concentrator, set DIP switch 8 up. If not, set the switch down.
DIP 8 Twisted Pair Polarity
UPOff
DOWNOn