Specifications

180 Chapter 14 Command display lists and spreadsheets
Note the following with regard to defaults in the Command Submaster
List display:
Pile-on is the default type for a newly defined submaster.
Bump status does not display unless changed from the default, which
is “enabled.”
Dwell time defaults to “manual.”
Rate does not display unless changed from the default, which is 100.
Editing submasters
Changes made to a submaster in the Command Submaster List are
immediately recorded. Edit in the Submaster List as follows.
9
Keystrokes: Actions:
1. Press [Blind]. Selects Blind display
2. Press[Sub] [S2], Sub List. Displays Submaster List
Select submaster number(s)
3. Press [7][3] [Enter]. Selects submaster 73. Prompt reads:
Select bump status and press
ENTER
(1=enabled, 2=disabled, 3=solo)
4. Press [1] [Enter].
a
a.
If not changing the bump status, for example if the submaster
is already enabled, you may just press [Enter].
Enables bump status for the
submaster. Prompt reads:
Enter upfade time
5. Press [5] [Enter]. Specifies 5 second upfade time
Prompt reads:
Enter dwell time
(For hold or manual operation, press
CLEAR until desired setting appears)
6. Press [1][5] [Enter]. Specifies 15 seconds dwell time
Prompt reads:
Enter downfade time
9.
Alternatively, you may press [Type], [Time] or [Label] keys to reach
the field you want.
Navigation and Feedback - Submaster List
[S]
±
Select a submaster XXX
Select a field XX
White row selected submaster
Yellow field selected field