Specifications
CEM+ Control Module
Sensor
®
+ Series
Americas
■
3030 Laura Lane, P.O. Box 620979, Middleton, WI 53562-0979 USA
■
Tel: +1 608 831 4116
■
Fax: +1 608 836 1736
■
Toll free: 800 688 4116
■
Toll free fax: 800 555 8912
Europe
■
Unit 5, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK
■
Tel: +44 (0)20 8896 1000
■
Fax: +44 (0)20 8896 2000
Asia
■
Room 605-606, Tower III Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong
■
Tel: +852 2799 1220
■
Fax: +852 2799 9325
Web: www.etcconnect.com
■
Email: (US) mail@etcconnect.com
■
(UK) mail@etceurope.com
■
(Asia) mail@etcasia.com
Copyright © 2003 ETC. All Rights Reserved. All product information and specifications subject to change. 7150L1001 Rev. A Printed in USA 11/03
SENSOR+ CONNECT
Sensor+ Connect duplicates the functions of the Control
Electronics Module (CEM+), but on your Emphasis server,
computer or even your PDA. This graphical user interface
(GUI) allows you to monitor rack activity, reconfigure
dimmer curves, record or activate presets – plus a whole
lot more.
Offers all the features needed to create, edit and download
specific information to the racks and modules.
FEATURES Configure rack and module information
Patch/Address 2 DMX Universes
File transfer capabilities
Record and activate 128 preset looks
Assign presets to up to 4 rooms
SYSTEM Emphasis server, Computer or PDA
REQUIREMENTS
Internet Browser Software such as
Internet Explorer 6.0 or better
Network connection (wired or wireless) to
a Sensor System with a CEM+ module
BROWSER NAVIGATION
LOGIN Security Level passwords determine screens
and modes available to user
HOME System Summary – Rack status, Active Presets,
Error List
RACKS Select a rack or all racks
View rack status, rack configurations, dimmer
configuration and rack specific errors
Rack Configuration
Name rack and set type of rack
Set Address mode: standard or advanced
Set Temperature Alarm
Select Power Balance – Column, Single
Phase or Three Phase
Configure Fan Time mode as Always On or
Off if no data/15 min.
Dimmer Search
Search for dimmer(s) by specifying a number
of search criteria – quick dimmer configuration
DIMMER Set dimmer name and module type
CONFIGURATION
Set dimmer mode: Normal, Dimmer Doubled
Switched, Fluorescent, Always On, Off
Set dimmer curve: Linear, Modified Linear,
Square, Modified Square and Sensor 2.0
Set Scale Voltage and Threshold levels
Select On/Off for Voltage Regulation, Preheat,
DC Output Prevention, and Inrush Protection
Set Temperature Reporting mode as F° or C°
PRESETS Assign Dimmers:
Assign dimmers to Rooms
Room 1, 2, 3 or 4:
Play or deactivate presets
Record presets from DMX, EDMX and Set levels
Set fade times and priority levels
Set Room Properties – name and maximum
number of active presets
PHYSICAL Panic
CONFIG Play or deactivate group-wide panic
Record and clear panic
Set panic properties: normally open or closed,
maintained or momentary, master level, and
option to force all non-panic dimmers to zero
Patch
Patch Configuration includes: Port
Enable, DMX Loss Behavior, Dimmer Number
Start, Length, Priority, Fade and Hold Time.
Network
Setup Group Network – IP Address, Netmask,
Gateway Address and Enable/Disable Network
File Transfer
Copy configuration files to a computer
(download)
Send updated configuration files to
CEM+ (upload)
Load Management
Record Loads and Report Load Errors
DIAGNOSTICS Dimmer Check
Set a dimmer to a level, with easy
dimmer advancement
Dimmer Level
Set dimmer(s) to a specified intensity.
Barbizon Light WPI Submittal Package Page 12 of 43