Specifications
SPECIFICATIONS
GENERAL Universal Control Electronics Module
Direct Ethernet connectivity for dimmer levels,
feedback and system control
UL, cUL LISTED and CE Marked
PHYSICAL Formed steel body finished with textured
epoxy paint
Injection molded face panel
Slide-in module installs and removes without tools
Spring-loaded module release
Airflow sensor to ensure adequate airflow
ELECTRICAL Accepts:
Single phase
Three phase WYE or Delta
Universal Voltage range 90-250 VAC
Line feed frequencies from 47-63Hz
Automatic frequency variation compensation
CONTROL 2-line by 20-character backlit LCD for system
FEATURES configuration, status display and error indication
Backlit 7-button keypad includes Reset button
4 status LED indicators: Power, Network activity,
DMX-A and DMX-B
Two configurable DMX512 inputs
(2500V opto-isolated)
128 user-programmable presets assignable
to 4 rooms
Maximum of 1024 racks (64 groups of 16)
Single Panic circuit with flexible programming
Complete group configuration stored in each CEM+
Individual CEM+ failure does not disable
multi-rack group
Replacement CEM+ can download configuration
from adjacent racks, rack back plane or online server
Multi-rack configuration can be restored from
a single CEM+
Dimmer outputs are regulated to
maintain constant power to loads ± 1V
Individual output scale voltage settings for load
wiring compensation (60 – 140V)
Selectable Dimmer Modes
Normal
Dimmer Doubled
Switched (unregulated on/off
with adjustable threshold)
Fluorescent with adjustable threshold
Always On
Off
Selectable Dimmer Output Curves
Linear
Modified Linear
Square
Modified Square
Sensor 2.0
40,000-Step Resolution per half cycle
Response speed <25mS
Selectable Data Loss Behavior
FEEDBACK All Sensor racks with CEM+s include basic system
diagnostic reporting
Remote monitoring, programming and backup
functions over the network using Sensor+
Connect or WYSILink software program
Standard rack feedback includes: DMX input
status, Rack power status, and Rack temperature
Advanced Features (AF) provides dimmer specific
status and load feedback (requires AF dimmer
rack and AF dimmer modules)
LOCAL PROGRAMMING MENU
RACK ERRORS View Error messages
ABOUT About Group: Software version, panic status,
preset status, and group name
About Network: IP address, SubNet mask
and Gateway
About Rack General: ambient temperature
and airflow, rack type, and air filter status
About Rack Power: frequency, voltage per
phase, and voltage headroom
About Rack Data: status for DMXA, DMXB,
and Network activity
About Rack Address: DMXA, DMXB or
EDMX start address, Rack Address mode
(Standard or Advanced)
About Dimmer: module type, curve,
scale voltage, output level, control source,
and module location
About Room: assign and monitor presets
in a room
Identify Rack: quick way to find and identify a
single rack in a group
LOGIN Security Level passwords determine screens
and modes available to user
PRESETS Play, deactivate or clear presets
Record presets from DMX, EDMX and set levels
Set fade times and priority levels
Name presets and rooms
Set maximum number of active presets per room
PANIC Activate, deactivate or clear group-wide panic
Record panic from DMX, EDMX and set levels
Record panic properties: normally open or closed,
maintained or momentary, master level,
and option to force all non-panic dimmers
to zero
DIMMERS Set dimmers at levels and release
Set dimmer curve
Name the dimmer
RACK Name rack and set type of rack
SETUP
Patch Capability
Set first dimmer and address mode
(standard or advanced)
Set Temperature Alarm
Set Power Balance – Column, Single Phase or
Three Phase
Set Air Filter Cleaning reminder based on hours
of use
Configure Fan as Always On or Off if no
data/15 min.
Select Data loss Behavior – Hold last Look, Wait
and fade, Crossfade to a Preset
GROUP Name Group
SETUP
Setup Group Network – IP Address,
SubNet mask, Gateway Address and
Enable/Disable Network
Set Data Priority per DMX port
Select Language – English, French, Spanish
or German
Select Temperature Reporting type - F° or C°
Set Login Timeout
Record Loads and Report Load Errors
Barbizon Light WPI Submittal Package Page 10 of 43