User's Manual

Table Of Contents
APPENDIX G
195M SPECIFICATIONS
Revised: 24 Jan 14 APX G-1
EST P/N AA107-195CM
Frequency of Operation (Software Selectable) 150 to 174 Mhz (6.25Khz / 12.5 Khz Channel Spacing)
Frequency Stability, -30C to +60C +/- 1.5ppm
RF Data Rate @ 6.25Khz channel spacing 4.8Kbps
RF Data Rate @ 12.5Khz channel spacing 9.6Kbps
Tx Output Power (Software Adjustable) 0.5 to 4 Watts
Tx Output Impedance 50 ohms
Rx Sensitivity -110 dBm
Rx Adjacent Channel Rejection > 55 dB
Modulation 4-Level GFSK
Forward Error Correction TCM, Coding Rate 3/4
Data Error Detection 32-Bit Cyclic Redundancy Check
FCC ID ENPESTEEM195M
Industry Canada Type Acceptance 2163 192 195M
LED Indicators
Power (48VDC, 12V-Aux), Status Multi-Color LED (Tx, Rx, Rx-Valid, Rx-Error), RS-
232 Tx/Rx, RS-485 Tx/Rx, RS-422 Tx/Rx, Ethernet Activity / Link
Data Packet Information
Radio Addressing 1-254 Total Units, Digi-repeating allows up to 3 repeaters between end-points
Data Packet Size 1-2000 Bytes
Serial Data Interface Buffer Size 8K bytes Tx / 8K bytes Rx
Data Retry Software Adjustable
Power Requirements
Receive / Without Ethernet Link 120 ma @ 12 VDC
Receive / With Ethernet Link 160 ma @ 12 VDC
Transmit @ 4 Watts RF Output 1540 ma @ 12 VDC
External 48 VDC Power Supply, EST P/N (tba) 30 Watts, RJ-45 Connector, Cat 5 Cable (300 Ft Maximum)
External DC Power Input 10.8 to 15 VDC
Input/Output Connectors
Ethernet Port (10/100) RJ-45 Female
Serial Data Interfaces (One of four selectable) Baud Rates 2400 to 115,200
1. RS-232 Port 1 (4-Wire) Tx,Tx-Gnd,Rx,Rx-Gnd RJ-45 Female (Shared with 48VDC Port)
2. RS-232 Port 2 (With Handshaking Signals) RJ-45 Female, Optional RJ-45 To DB9, 3-Wire Adaptor Available
3. RS-485 Port RJ-45 (Shared With 4-20 mA Sensor Port)
4. RS-422 Port RJ-45 (Shared With Ethernet Port)
4-20 mA I/O RJ-45 Female (Shared With RS-485 Port)
Antenna Input/Output TNC Female Connector
External DC Input Power Mini-Combicon, 3 pin female
Serial Data Interface, Master PLC mode protocols
supported by auto-digi-repeater function
Allen Bradley DF1, Opto22, Modbus RTU/ASCII, and Transparent protocols
Ethernet Interface protocols supported for remote
access via ARP proxy on Master Gateway Unit
ICMP Echo (ping), Modbus/TCP (Aux Voltage, 4-20mA readings, RSSI, MCU Core
Temperature), Remote Configuration
Ethernet Interface protocols (direct access only) Telnet, IP Configuration, Firmware upgrades
Temperature Range -30° to +60° C
Humidity 95% Non-condensing
Dimensions 1.9 in. H x 6.7 in. W x 6.2 in. L
Weight 1.25 lbs.
Product Warranty 1 Year
Outdoor Pole Mount Kit AA195PM
48 VDC Power Supply TBD
RJ-45 To DB9 Serial Adaptor TBD
RJ-45 To Terminal Block Adaptor TBD
Antennas/Surge Protectors/Cables, etc. Contact factory for various options (market@esteem.com or 509-735-9092)
Options
ESTeem 195M Specifications
Mechanical / Environmental
Protocols
Transmiter/Receiver