3. By default, the ENC Utility sets all ESTeem modems in AP Bridge
mode. To change the Plant Router ESTeem to AP Router mode, double-
click on the icon to bring up the ESTeem Summary window and press
the Edit button (Figure 20).
4. Change the Mode of Operation from AP Bridge to AP Router
(or Masquerade if desired) and press the Next button at the bottom of the
window (Figure 21).
5. Continue through the configuration screens setting the AP Router
addressing to match the IP address ranges for your network. For
help with setting the router addressing please refer to Router Address
Examples later in this chapter. You will end on the screen in Figure
22. Press the Finish button to return to the configuration page.
6. Verify all ESTeem modems are connected to the same switch as the
computer running the ENC Utility and send the configuration to all
modems at the same time by selecting ESTeem>ESTeem
Configuration>Send Configuration to All ESTeems. Once the ENC
Utility has downloaded the configuration for both ESTeem
195C/Ms, the status box around the ESTeems will change from
yellow to blue. This indicates that the configuration was completed
successfully and the ESTeem 195C/Ms are ready to be installed in
the application.
Revised: 24 Jan 14 3-12 EST P/N AA107-195CM
Figure 21: AP Router Configuration
Figure 22: ESTeem Summary Page