User's Manual

APPENDIX A
SOFTWARE COMMANDS
Revised: 4 Feb 14 APX A-6 EST P/N AA107-195CM
The save command. The execution of this command stores the current command values and switches.
Note: Please wait approximately two seconds after executing the SAVE command before turning off power to the ESTeem.
s/n
Serial Number command. When executed from the Command Model will output the ESTeem serial number of the unit that is
defined at the time of manufacturer.
sdi
Sets the serial device interface (sdi) for the ESTeem 195C/M. Any serial port not configured as the sdi can be used as a console
port for programming. The sdi can also be placed in console mode by entering three pluses (+++) in the port within three seconds
of a reboot of the ESTeem 195C or 195M. Factory default = 2 (Port 3 –RS-232 with Full Handshake Lines)
0 = No serial data interface (All console ports)
Technical Tip: A three second delay is
added after a reset before the ESTeem
195C or 195M will process any data
through the serial interface. This time
allows entry of the console break
sequence to program (+++).
1 =
RS-232 Port 4 (3 wire RS-232 only with remote power)
2 = RS-232 Port 3 (Full RS-232 with hardware handshaking)
3 = RS-485 Port 1
4 = RS-422 Port 2
5 = TCP Socket Port 2 (Custom software interface required)
6 = UDP Socket Port 2 (Custom software interface required)
Note: Port pin-out information found in Appendix B (Interface Ports)
setcon (r1,r2,r3,da)
This command defines the destination address for the ESTeem to perform a connect when data arrives in the configured serial
device interface (sdi). This function supports a direct connect or a connect through a maximum of three repeaters.
r1 = ESTeem address (1 to 254) of repeater 1.
r2 = ESTeem address (1 to 254) of repeater 2.
r3 = ESTeem address (1 to 254) of repeater 3.
da = Destination address (1 to 255).
sread
This command will complete an instantaneous read of the values in the four 4/20mA sensors.
stopbits (1-2)
This command sets the number of stop bits for the serial device interface. This command is used with baud, parity, databits to
configure the serial port on the ESTeem. Factory default = 1.
termt (0-5000)
The serial device interface, receive termination timer value. This value is the time after the last serial data bit is received in the
serial buffer that the modem will wait for further data. If additional data is received from the device, the ESTeem will make an RF
packet and send to the remote ESTeem. This value can be 0 to 5000 milliseconds. Factory default = 6O.
txdelay (0-500)