APPENDIX A
SOFTWARE COMMANDS
Revised: 4 Feb 14 APX A-2 EST P/N AA107-195CM
This command sets the baud rate for the serial device interface (SDI). The other commands are the data bits, parity and stop bits
cert
This command will display the certification for the ESTeem 195C/M. The FCC ID, Canadian DOC ID and serial number of the
modem will be displayed.
chspace (1-2)
This command will set the channel spacing for the ESTeem 195C/M.
1 = 6.25 kHz channel spacing
2 = 12.5 kHz channel spacing
Factory default = 2 (12.5 kHz channel spacing)
connect (r1,r2,r3,da)
This command performs the connect to a destination ESTeem. This function supports a direct connect or a connect through a
maximum of three repeater nodes.
r1 = ESTeem address (1 to 254) of repeater 1.
r2 = ESTeem address (1 to 254) of repeater 2.
r3 = ESTeem address (1 to 254) of repeater 3.
da =Destination address (1 to 254).
csthresh (-150 through -50)
This command is the carrier sensed threshold for the receiver in the ESTeem 195C/M. The values are listed in dBm and must be
entered with the negative (-) value before the command. Adjustment of this command is only necessary in very high noise
environments. Factory default = -80dBm.
databits (7-8)
This command sets data bits in the serial device interface. This command used with baud, parity and stopbits commands.
Factory default = 8.
disack (on/off)
This command when enabled instructs the modem to disable the acknowledgment request on the information packet. This is used
when the designation device will respond with its own acknowledgment. Factory default = off.
on: Enabled
off: Disabled
disconnect
The disconnect command. The execution of this command immediately initiates a disconnect request with the currently connected
node.
eth_bridge (on/off)