User's Manual
Table Of Contents
- Front Cover 195CM
- Table of Contents 195CM
- Chapter 1 - Introduction 195CM
- Chapter 2 - Starting Out 195CM
- Chapter 3 - Example Applications 195CM
- Chapter 4 - Repeating 195CM
- Chapter 5 - Ethernet Configuration and Applications 195CM
- Chapter 6 - Utilities and Features 195CM
- Chapter 7 - Antenna Setup 195CM
- Apx A - Software Commands 195CM
- Apx B - Interface Ports 195CM
- Apx C - Model 192 Integration 195CM
- Apx D - FCC Information
- Apx E - 195C Specifications
- Apx F - 195M Specifications
CHAPTER 3
EXAMPLE APPLICATIONS
Point to Point Transparent Example 2 (Figure 2)
Technical Tip: The unit address of the ESTeem
195C or 195M is the last octet of the IP address.
This single address is used when configuring the
destination and routing. Example – Main
Address IP = 172.16.10.182. Unit address = 182.
(3) ESTeem
M
odel 195C
Transparent RS-232 Wireless Link
465.500 MHz at 2 Watts Output
Main Office Address – 172.16.10.182
Remote Site Address – 172.16.10.183
Repeater Site Address – 172.16.10.200
The following are the software commands that need to be adjusted for point to point operation with a repeater. For a complete
list of software commands and their definition, please refer to Appendix A (Software Commands) of this User’s Manual:
Main Office
Name Command Setting Notes
IP Address ip_addr 172.16.10.182 Set with Discovery Utility in setup above
Frequency frequency 465.500 Listed in MHz and set to operating frequency of network
RF Power rfpower 2 Watts Drop down menu 0.5 to 4 Watts - Output power on FCC license
Serial Data Interface sdi RS-232 Full
Handshake (port 3)
Drop down menu for configuring which port will transfer data
Baud Rate baud 19200 Configure serial port data rate
Setconnect Address setc 200,183 ESTeem address where data will be sent. Note the repeater site
address in the communications path.
Terminal Timer termt 10 Time gap in serial data before making RF packet and sending to
remote ESTeem (milliseconds)
Remote Site
Name Command Setting Notes
IP Address ip_addr 172.16.10.183 Set with Discovery Utility in setup above
Frequency frequency 465.500 Listed in MHz and set to operating frequency of network
RF Power rfpower 2 Watts Drop down menu 0.5 to 4 Watts - Output power on FCC license
Serial Data Interface sdi RS-232 Full
Handshake (port 3)
Drop down menu for configuring which port will transfer data
Baud Rate baud 19200 Configure serial port data rate
Setconnect Address setc 200,182 ESTeem address where data will be sent. Note the repeater site
address in the communications path.
Terminal Timer termt 10 Time gap in serial data before making RF packet and sending to
remote ESTeem (milliseconds)
Repeater Site
Name Command Setting Notes
IP Address ip_addr 172.16.10.200 Set with Discovery Utility in setup above
Frequency frequency 465.500 Listed in MHz and set to operating frequency of network
RF Power rfpower 2 Watts Drop down menu 0.5 to 4 Watts - Output power on FCC license
The above software commands can be adjusted in the “All” commands radial or found in their individual sections such as
“Interface” and “Radio” (Figure 8).
Once all the above software commands are adjusted to their correct parameters, press the Write Config button to send the
changes to the 195C or 195M. The modem will reset and be ready for operation on the selected serial port. Complete the
above steps for both radio modems in the network and proceed to installation and testing.
Revised: 10 Feb 14 3-8 EST P/N AA107-195CM