User's Manual

CHAPTER 3
EXAMPLE APPLICATIONS
Point to Point Transparent Example 1 (Figure 1)
(2) ESTeem Model 195C
Transparent RS-232 Wireless Link
465.500 MHz at 2 Watts Output
Main Office Address – 172.16.10.182
Remote Site Address – 172.16.10.183
The 195 Series Narrow Band Configuration Tool
provides a graphical interface to the individual software
commands for the ESTeem 195C or 195M. On the
Configuration tab the software commands can be
displayed by their category. To display the status of all
software commands select the “All” commands radial and
press the Read Config button (Figure 7).
Figure 7: Model 195C/M Configuration Utility
Technical Tip: The unit address of the ESTeem
195C or 195M is the last octet of the IP address.
This single address is used when configuring the
destination and routing. Example – Main
Address IP = 172.16.10.182. Unit address = 182.
The fol
lowing are the software commands that need to be adjusted for point to point operation. For a complete list of software
commands and their definition, please refer to Appendix A (Software Commands) of this User’s Manual:
Main Office
Name Command Setting Notes
IP Address ip_addr 172.16.10.182 Set with Discovery Utility in setup above
Frequency frequency 465.500 Listed in MHz and set to operating frequency of network
RF Power rfpower 2 Watts Drop down menu 0.5 to 4 Watts - Output power on FCC license
Serial Data Interface sdi RS-232 Full
Handshake (port 3)
Drop down menu for configuring which port will transfer data
Baud Rate baud 19200 Configure serial port data rate
Setconnect Address setc 183 ESTeem address where data will be sent. Usually the unit address
of remote ESTeem.
Terminal Timer termt 10 Time gap in serial data before making RF packet and sending to
remote ESTeem (milliseconds)
Remote Site
Name Command Setting Notes
IP Address ip_addr 172.16.10.183 Set with Discovery Utility in setup above
Frequency frequency 465.500 Listed in MHz and set to operating frequency of network
RF Power rfpower 2 Watts Drop down menu 0.5 to 4 Watts - Output power on FCC license
Serial Data Interface sdi RS-232 Full
Handshake (port 3)
Drop down menu for configuring which port will transfer data
Baud Rate baud 19200 Configure serial port data rate
Setconnect Address setc 182 ESTeem address where data will be sent. Usually the unit address
of remote ESTeem.
Terminal Timer termt 10 Time gap in serial data before making RF packet and sending to
remote ESTeem (milliseconds)
Revised: 10 Feb 14 3-6 EST P/N AA107-195CM