User's Manual

CHAPTER 3
EXAMPLE APPLICATIONS
Modes Of Operation
The ESTeem Model 195C and 195M are sophisticated wireless networking devices that can be configured for multiple serial
and Ethernet interfaces. Determining the correct mode of operation for the ESTeem is the first step in creating a reliable
wireless network. This chapter will explain each mode of operation, provide example applications and detailed programming
information for each mode. Please review the following modes of operations. If you do not see an example of your
application, please contact ESTeem support at 509-735-9092 for help in selecting your mode of operation.
Transparent Point to Point Application
The most commonly used mode of operation with the ESTeem Model 195C/M is the transparent mode. Point to point
operation is when two serial or Ethernet devices are transferring information between either other, directly or through a
repeater (Figures 1 and 2). The type of serial data interface (RS-232, RS-422, RS-485 or Ethernet) on either end of the
wireless link is configurable and can be independent on each side. For example, the Main Office in Figure 1 can be configured
for RS-232 operation, while the serial port at the remote site can be configured for RS-485.
Example Applications
Point to point serial interfaces (RS-232, RS-422 or RS-485)
Point to point wireless Ethernet communication devices
Remote Supervisory Control and Data Acquisition (SCADA) networks
Applications Where Transparent Mode Not Used
Multiple Remote Locations
PLC Emulation Networks (see PLC Emulation below)
Connections to large Ethernet traffic networks such as large office buildings or plant networks
Figure 1: Point to Point Example
Revised: 10 Feb 14 3-1 EST P/N AA107-195CM