User's Manual

APPENDIX D
SOFTWARECOMMANDS
Definitions
Listed below in alphabetical order are the definitions of the ESTeem software commands.
Revised: 27 Mar 01
APX D-8
SEL/N2 (1-999)
The SEL/N2 command sets the transceiver for a specific
frequency.
SETCon (r1,r2,r3,da)
This command defines the destination address for the
ESTeem to perform a connect using the Auto Connect
feature. This function supports a direct connect or a
connect through a maximum of three repeaters.
r1 = ESTeem address (1 to 254) of repeater 1.
r2 = ESTeem address (1 to 254) of repeater 2.
r3 = ESTeem address (1 to 254) of repeater 3.
da = Destination address (1 to 254).
S/N
Serial Number command. When executed from the
Command Model will output the ESTeem serial number of
the unit that is defined at the time of manufacturer.
SQDCTRL (on/off)
This function enables the Square D controller protocol. For
further detail Reference the EST Engineering Report on
Square D controller interfacing.
Factory default = OFF.
SQDADD (1-254)
This function is used with the SQDCTRL command to
control the address fence when using SQ-D Network
Interface Modules. For further details reference the EST
Engineering Report on the SQ-D controller.
Factory default = 0.
SQUELCH (0-3)
This command defines the squelch threshold of the
receiver. Listed below are the settings:
0 = -101 dBm 2
P
V
1 = - 93 dBm 5
P
V
2 = - 87 dBm 10
P
V
3 = - 70 dBm 70
P
V
Factory default = 0.
TERMCont (on/off)
The RS-232C/422/485 receive termination timer.
ON: If there are characters in the RS-232 buffer and
the modem is in Converse Mode, the termination
timer starts from the time the last receive character
is updated in the buffer. If the termination time
expires before another character is received, the
characters are transmitted.
OFF: Disabled
Factory default = OFF.
TERMTime (10-65535)
The RS-232C/422/485 receive termination timer value.
This value can be 10 to 65535 milliseconds. This value is
enabled by TERMCONT. Factory default = 5O.
TRANSPAR (on/off)
The transparent mode command. This mode allows the
ESTeem link to be completely transparent to the
communicating RS-232/422/485 devices. Reference
Chapter 2.
ON: Enabled.
OFF: Disabled.
Factory default = OFF.
TXSTAT
This command outputs the total number of rf transmissions
vs. the total number of retries. After output is completed,
the counter is zeroed.
TYPerr (on/off)
This command enables the Communication Error
Messages.
ON: Enabled.
OFF: Disabled.
Factory default = OFF.