User's Manual
Table Of Contents
APPENDIX D
SOFTWARECOMMANDS
Definitions
Listed below in alphabetical order are the definitions of the ESTeem software commands.
Revised: 27 Mar 01
APX D-5
MODUlate (on/off)
The radio modulate command. When enabled will transmit
a modulated test signal when the RADIO ON command is
enabled.
ON: Enabled.
OFF: Disabled.
Factory default = OFF.
MOORE (on/off)
This function enables the Moore products using Hart
protocol. For further details reference the EST Engineering
Report on Moore Products interfacing.
ON: Enabled.
OFF: Disabled.
Factory default = OFF.
MULTID (on/off)
This command when enabled allows the ESTeem User to
send data to another ESTeem from the CONVERSE
MODE by specifying the routing address before the data.
ON: Enabled.
OFF: Disabled.
Factory default = OFF.
Example Of Transmitted Data:
[001]DATA Routes data to an ESTeem addressed 1.
[100,200,250,1]DATA Routes data to an ESTeem
addressed 1 via ESTeems
addressed 100, 200, and 250.
This replaces using the CONNECT command from the
COMMAND Mode. Received data packets will have the
address of the ESTeem that sent the data at the beginning
of the data packet.
Example Of Received Data:
[004]RECEIVED DATA Data received from an ESTeem
addressed 4.
[030,100,244,004] Data received from an ESTeem
addressed 4 via ESTeems
addressed 30, 100, and 244.
NETwork (0-255)
Network identification code. This is used to program a
common code for all modems in the customers network so
that another facility on your frequency using the same
addresses will not interfere with your equipment. Factory
default = 37.
OPTO (on/off)
This function enables the Opto 22 protocol. For further
details reference the EST Engineering Report on Opto 22
interfacing.
ON: Enabled.
OFF: Disabled.
Factory default = OFF.
PACKleng (1-2000)
This command defines the length of the data packet in
bytes. Factory default = 2000.
PACKMon (on/off)
Places the ESTeem in the packet monitor mode. Factory
default = OFF.
PHone (on/off)
Phone port enable command. The ESTeem will answer an
incoming call when enabled.
ON: Enabled.
OFF: Disabled.