User's Manual

APPENDIX D
SOFTWARECOMMANDS
Definitions
Listed below in alphabetical order are the definitions of the ESTeem software commands.
Revised: 27 Mar 01
APX D-4
HElp
HELP switches are:
HELP Displays this Help menu.
HELP ALL Displays All commands switches
and arguments.
HELP CHANGE Displays only the commands that
are changed from factory default.
HELP CONTROL Displays Control commands
switches and arguments.
HELP PLC Displays PLC commands switches
and arguments.
HELP RADIO Displays Radio commands switches
and arguments.
HELP RS-232 Displays RS232 commands
switches and arguments.
HELP SETUP Displays Setup commands switches
and arguments.
HELP SYSTEM Displays System commands
switches and arguments.
JOHNctrl (on/off)
This function enables the Johnson controller protocol. For
further detail Reference the EST Engineering Report on
Johnson controller interfacing.
ON: Enabled.
OFF: Disabled.
Factory default = OFF.
LAT
Latches the selection of the desired serial frequency
synthesizer on the Tx/Rx card
MESSform (on/off)
When enabled all of the system status and error messages
will be in a formatted form.
"xx" indicates what error or message (See Error
Messages and System Status Messages).
EMxx <CR> [ESTeem Error Messages]
SExx <CR> [System Error Messages]
SSxx <CR> [System Status Messages]
SSxx-xxxx <CR> [System Status Message
W/Returned Value]
ON: Enabled.
OFF: Disabled.
Factory default = OFF.
MOdecontr (on/off)
ON: The mode of the ESTeem modem is controlled by
pin 19 of the RS-232C connector. A low (0)
directs the ESTeem into the COMMAND mode.
A high (1) directs the ESTeem into
CONVERSE/TRANSPARENT mode.
OFF: The mode of the ESTeem modem is controlled by
ASCII character.
Factory default = OFF
MODEL (xx)
Displays the product model of default firmware that is
installed. Model should be the same as product being used.
Listed below are the model codes
19C = ESTeem Model 192C
19F = ESTeem Model 192F
19V = ESTeem Model 192V
MODCTRL
This command enables the Modicon controller protocol.
For further detail Reference the EST Engineering Report
on Modicon controller interfacing.
OFF: Disabled.
Factory default = OFF.