User's Manual
Table Of Contents
CHAPTER 3
PROGRAMMING ESTEEM FEATURES
Revised: 27 March 01
3-4
Example Of Transmitted Data
:
[001]DATA Routes data to an ESTeem addressed 1.
[100,200,250,1]DATA Routes data to an ESTeem
addressed 1 via ESTeems
addressed 100, 200, and 250.
The above example replaces the CONNECT command
from the COMMAND Mode.
Received data packets will have the address of the
ESTeem that sent the data at the beginning of the data
packet.
Example Of Received Data
:
[004]RECEIVED DATA Data received from an
ESTeem addressed 4.
[030,100,244,004] Data received from an ESTeem
addressed 4 via ESTeems
addressed 30, 100, and 244.
MULTID (on/off) = On Enables this feature. Factory
default = OFF.
REMOTE PROGRAMMING
The Remote Programming feature allows the user to
remotely program ESTeems in his network. When a
connection has been made with the remote ESTeem the
RPG: prompt will be displayed showing that you are now
in the COMMAND mode of that remote ESTeem.
To enable this feature perform the following from the
COMMAND MODE:
PROG (1-254) Address of destination ESTeem.
Note:
You can also use the Repeater routing
(r1,r2,r3,da) to reach the destination ESTeem.
(r1 = address of first repeater, r2 = address of
second repeater, etc. da = destination address).
To end a remote programming session, hold Control and
type C (^C) and you will return to the COMMAND
prompt of your ESTeem. There is a Watch Dog Timer
that will automatically disconnect you from remote
programming if there is no activity for thirty seconds.
The REMPROG (on/off) feature is used to defeat the
ability of your ESTeem from being remotely
programmed. If REMPROG = OFF another ESTeem
cannot remotely program your unit. Factory default =
ON.
SECURITY
The Security feature allows the user to lock out
programming of the ESTeem. REMEMBER TO STORE
YOUR CODE NUMBER IN A SAFE PLACE.
To enable this feature perform the following from the
COMMAND MODE:
SECURITY (1 to 100,000) Entering a security
number enables the
security feature.
SAVE To enter the security code permanently into the
ESTeem memory.
Note: When enabled, the ESTeem will output a
“Security On” message.
To disable the security feature perform the following
from the COMMAND mode.
SECURITY (1 to 100,000) Entering your security
number disables the
security feature.
SAVE To remove the security code permanently from
the ESTeem memory.
Note: When disabled, the ESTeem will output a