User's Manual

CHAPTER 1
STARTING OUT
Revised: 27 Mar 01 1-6
Note Appendix E of this manual will have the
complete listing of software commands and
categories for the factory default of the
ESTeem.
Saving A Program
A program is saved by typing in the SAVE command at
the CMD: prompt. The programming variables that have
been changed will be written to the non-volatile memory.
The programming parameters will be loaded each time
the modem is powered up or reset.
Restoring Factory Defaults
The ESTeem has a very simple procedure to restore the
program variables in the unit to the factory default
setting. When the FA<cr> command is entered from the
command mode the ESTeem will be configured from a
variable table located in its EPROM. It is a good practice
to restore the ESTeem to a factory defaults before any
programming of the unit.
To ensure the modem is in the COMMAND MODE set it
back to the factory default by performing the following:
1.
Set both switches (#1&2) on the RS-232 setup
switches to the OFF position.
2.
Reset the ESTeem.
3.
Verify the computer's Comm port is configured for
19,200,N,8,1.
4.
Type FA<cr> and the ESTeem welcome message
should be displayed. The characters may not be
echoed on the screen.
5.
Type SA<cr> to save the factory default table.