User's Manual

RF Switch Interface, v1.0 Installation Guide
www.elec-solutions.com © 2012 Electronic Solutions, Inc. Page 9 of 10
Troubleshooting
Problem
Solution
Can’t set limits or toggle motor
direction using the RF Switch
Interface.
The RF Switch Interface only provides RF communication from a dry
contact device to an ESI RF network and cannot be used to
administer an ESI RF network.
Use a SUITE remote to administer (set up and configure) an ESI RF
network.
The battery life lasts only a few
hours.
Maintained Switches -- do not use. The battery will run down quickly.
The RF Switch Interface does not support any type of maintained
switch.
Motor doesn’t move when button is
pressed on RF Switch Interface.
Check all wiring and connections.
Solid conductor wire must be used.
Stranded wire with stray strands touching other contacts can disable
the circuit. Stranded wire is not recommended.
Ensure that the RF Switch Interface is properly joined to a working
ESI RF network.
Upper and Lower limits MUST be set on a motor in order for the Puck
to control that motor.
Net Group control is lost.
If the Set Net Group operational mode was used to change the Net
Groups, and a Reset was performed on the RF Switch Interface, the
Net Groups will be reset back to default.
Use ―Set Net Group‖ to change to the correct Net Group.
Net Groups
1, 2, 3, 4 (the Default)
5, 6, 7, 8
9, 10, 11, 12
13, 14, 15, 16
Change DIP Switch settings after the
RF Switch Interface is powered up.
Remove the battery.
Change the DIP Switch settings.
Install the battery.
For questions, please contact your ESI distributor.
OPERATION
A single RF Switch Interface communicates to a single ESI RF network, which is controlled by a wall switch.
The RF Switch Interface is typically attached to a wall switch that has a Center Off position.
Rocker Switch
Up shade moves toward open position
Center off
Down shade moves toward close position