User's Manual
RF Switch Interface, v1.0 Installation Guide
www.elec-solutions.com © 2012 Electronic Solutions, Inc. Page 5 of 10
Mode
Description
DIP Switch setting
Latch and
Run
Required Switch Type = SPDT Momentary (SPCO)
Motor moves toward limit as long as an Open or Close button
is pressed and held.
If the button is released within 1.5 seconds, then the motor
stops.
If the button is held for more than 1.5 seconds, then released,
the motor will latch and run to limit.
SPST
(single pole
single throw)
Required Switch Type = SPST Momentary “Garage door”
Single Press
Motor moves toward limit when button is pressed and
released.
If button is pressed and released again (before motor
reaches a limit), then motor reverses direction and moves
toward the other limit. The direction of travel toggles after
each button press.
Double Press
If button is pressed and released two times within 0.5 second
while the motor is moving, then the motor stops.
NOTE: the next time the button is pressed, the motor will
move toward the other limit.
Tilt 1
Typically used
for blinds with
small vanes.
Required Switch Type = SPDT Momentary (SPCO)
Pulse duration = 40 milliseconds.
Single Press
Motor pulses toward limit when Open or Close button is
pressed and held.
Motor stops pulsing when button is released or motor
reaches a limit.
Double Press
If an Open or Close button is pressed and released two times
within 0.5 second, the motor will run to limit.
Tilt 2
Typically used
for blinds with
medium
vanes.
Required Switch Type = SPDT Momentary (SPCO)
Pulse duration = 60 milliseconds.
Single Press
Motor pulses toward limit when Open or Close button is
pressed and held.
Motor stops pulsing when button is released or motor
reaches a limit.
Double Press
If an Open or Close button is pressed and released two times
within 0.5 second, the motor will run to limit.
Tilt 3
Typically used
for blinds with
large vanes.
Required Switch Type = SPDT Momentary (SPCO)
Pulse duration = 100 milliseconds.
Single Press
Motor pulses toward limit when Open or Close button is
pressed and held.
Motor stops pulsing when button is released or motor
reaches a limit.
Double Press
If an Open or Close button is pressed and released two times
within 0.5 second, the motor will run to limit.