User's Manual
Clear Limits
1. Enter administrative mode.
2. Press and release Close while in administrative mode to clear the programmed limits. This will be indicated
by a short flash on the motor LED. The Motor LED will flash after exiting administration mode to indicate the
limits have been cleared.
Reset To Factory
1. Enter administrative mode.
2. Press and release both Open and Close simultaneously to reset the motor to factory defaults. This will clear
limits, reset the motor direction, and clear Z-Wave network information.
WARNING!
Resetting a motor to factory that has been included into a Z-Wave network will effectively orphan the motor from
the network, causing the Z-Wave Controller to be unable to control the drapery motor. It may cause other
problems for the Z-Wave network such as 1) slow network operation, 2) failure of Controller(s) to communicate
with other nodes in the Z-Wave network. Do not use factory reset on an IMS motor that is part of a working Z-
Wave network to clear the limits. Use the Clear Limits feature instead. Do not use factory reset on an IMS motor
that is part of a working Z-Wave network to remove it from the network. Follow the directions for the Z-Wave
controller to Exclude a slave from the network. If the Z-Wave network is controlled by a single Z-Wave Controller
that does not provide an Exclude from Network feature, then the Z-Wave Controller must be reset to factory, and
ALL SLAVE NODES must be reset to factory.
NOTE
The Forest IMS Motor is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Z-
Wave enabled devices displaying the Z-Wave logo can also be used with Forest IMS regardless of the
manufacturer. Forest IMS can also be used in other manufacturer’s Z-Wave enabled networks and all listening
devices act as repeaters, regardless of vendor.
NOTE
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
Changes or modifications not expressly approved by Forest Group and Electronic Solutions, Inc. could void the